<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://wiki.siwenoid.com/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=91.82.214.70</id>
	<title>Siwenoid Wiki - User contributions [en]</title>
	<link rel="self" type="application/atom+xml" href="https://wiki.siwenoid.com/api.php?action=feedcontributions&amp;feedformat=atom&amp;user=91.82.214.70"/>
	<link rel="alternate" type="text/html" href="https://wiki.siwenoid.com/index.php?title=Special:Contributions/91.82.214.70"/>
	<updated>2026-10-18T08:00:31Z</updated>
	<subtitle>User contributions</subtitle>
	<generator>MediaWiki 1.40.0</generator>
	<entry>
		<id>https://wiki.siwenoid.com/index.php?title=Config_file_parameters&amp;diff=401</id>
		<title>Config file parameters</title>
		<link rel="alternate" type="text/html" href="https://wiki.siwenoid.com/index.php?title=Config_file_parameters&amp;diff=401"/>
		<updated>2010-09-25T07:57:27Z</updated>

		<summary type="html">&lt;p&gt;91.82.214.70: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Szerver parancssori paraméterei&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
A szerver indításához minimálisan a &#039;&#039;&#039;java -jar Siwenoid.jar&#039;&#039;&#039; parancs szükséges. A további paramétereket a &#039;&#039;&#039;java&#039;&#039;&#039; és a &#039;&#039;&#039;-jar&#039;&#039;&#039; közé kell megadni. Főbb beállítási lehetőségek:&lt;br /&gt;
*-Dsiwenoid.registry.port=1099&amp;lt;br /&amp;gt;A szerver saját magát menedzselő RMI portja, ezen keresztül tudja például ellenőrizni induláskor, hogy fut-e már másik példány a számítógépen. Alapértelmezetten: 1099.&lt;br /&gt;
*-Dhajdbc.home=..path..&amp;lt;br /&amp;gt;Ezzel a beállítással lehet befolyásolni, hogy a HA-JDBC modul hol keresse a konfigurációs fájlját. (Általában nem kell megváltoztatni az alapértelmezettet.)&lt;br /&gt;
*-Xms128m&amp;lt;br /&amp;gt;A szerver induláskor ennyi memóriát foglaljon le.&lt;br /&gt;
*-Xmx1024m&amp;lt;br /&amp;gt;A szerver a futása során legfeljebb ennyi memóriát használhat. Az 1024m azt jelenti, hogy maximum 1024 MB. A javasolt beállítás kisebb rendszereknél -Xmx512m nagyobbaknál -Xmx1024m.&lt;br /&gt;
&lt;br /&gt;
További parancssori argumentumok (a parancs után kell írni őket szóközzel elválasztva):&lt;br /&gt;
*-start&amp;lt;br /&amp;gt;Elindítja a szervert (ez az alapértelmezett).&lt;br /&gt;
*-stop&amp;lt;br /&amp;gt;Leállítja a futó szervert.&lt;br /&gt;
*-restart&amp;lt;br /&amp;gt;Újraindítja a futó szervert.&lt;br /&gt;
*-version&amp;lt;br /&amp;gt;Kiírja a szerver verziószámát.&lt;br /&gt;
&lt;br /&gt;
&#039;&#039;&#039;Szerver oldali XML konfiguráció&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
*Siwenoid&amp;lt;br /&amp;gt;Gyökér elem, az XML szabvány szempontjából fontos, minden dokumentumnak pontosan egy gyökere van.&lt;br /&gt;
**Services&amp;lt;br /&amp;gt;A szerver által használt szervízek sorrendhelyes felsorolása. Ez alatt minden egyes elem Tag-je a szervíz osztályának egyszerű neve, tartalma pedig az osztály teljes (minősített) neve. Pl.:&amp;lt;br /&amp;gt;&amp;lt;CacheService&amp;gt;hu.siwena.services.cache.CacheService&amp;lt;/CacheService&amp;gt;&amp;lt;br /&amp;gt;&amp;lt;DatabaseService&amp;gt;hu.siwena.services.database.DatabaseService&amp;lt;/DatabaseService&amp;gt;&amp;lt;br /&amp;gt;&lt;br /&gt;
...&lt;br /&gt;
**LoggerService&amp;lt;br /&amp;gt;A logolásért felelős szervíz konfigurációja, a log4J modulnak megfelelően.1 Legegyszerűbb konfigurációja például:&lt;br /&gt;
&amp;lt;log4j:configuration xmlns:log4j=&amp;quot;http://jakarta.apache.org/log4j/&amp;quot;&amp;gt;&lt;br /&gt;
		&amp;lt;appender name=&amp;quot;root_fileappender&amp;quot; class=&amp;quot;org.apache.log4j.DailyRollingFileAppender&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;File&amp;quot; value=&amp;quot;log/siwenoid.log&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;Append&amp;quot; value=&amp;quot;true&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;ImmediateFlush&amp;quot; value=&amp;quot;true&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;layout class=&amp;quot;org.apache.log4j.PatternLayout&amp;quot;&amp;gt;&lt;br /&gt;
		      		&amp;lt;param name=&amp;quot;ConversionPattern&amp;quot; value=&amp;quot;[%d] - %m%n&amp;quot;/&amp;gt;&lt;br /&gt;
 &amp;lt;/layout&amp;gt;&lt;br /&gt;
		 &amp;lt;/appender&amp;gt;&lt;br /&gt;
		&amp;lt;logger name=&amp;quot;hu.siwena&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;level value=&amp;quot;info&amp;quot;/&amp;gt;&lt;br /&gt;
			&amp;lt;appender-ref ref=&amp;quot;root_fileappender&amp;quot;/&amp;gt;&lt;br /&gt;
		&amp;lt;/logger&amp;gt;&lt;br /&gt;
		&amp;lt;appender name=&amp;quot;dbappender&amp;quot; class=&amp;quot;hu.siwena.services.database.synchronization.DatabaseErrorAppender&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;layout class=&amp;quot;org.apache.log4j.PatternLayout&amp;quot;&amp;gt;&lt;br /&gt;
				&amp;lt;param name=&amp;quot;ConversionPattern&amp;quot; value=&amp;quot;%m%n&amp;quot;/&amp;gt; 				&lt;br /&gt;
			&amp;lt;/layout&amp;gt;&lt;br /&gt;
		&amp;lt;/appender&amp;gt;&lt;br /&gt;
		&amp;lt;logger name=&amp;quot;net.sf.hajdbc&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;level value=&amp;quot;debug&amp;quot;/&amp;gt;&lt;br /&gt;
			&amp;lt;appender-ref ref=&amp;quot;dbappender&amp;quot;/&amp;gt;&lt;br /&gt;
		&amp;lt;/logger&amp;gt;&lt;br /&gt;
		 &amp;lt;root&amp;gt;&lt;br /&gt;
		 	 &amp;lt;level value=&amp;quot;error&amp;quot;/&amp;gt;&lt;br /&gt;
		  &amp;lt;/root&amp;gt;&lt;br /&gt;
	&amp;lt;/log4j:configuration&amp;gt;&lt;br /&gt;
DatabaseService&lt;br /&gt;
Az adatbázist kezelő szervíz konfigurációja.&lt;br /&gt;
database (Attribútumok: id=”str” host=”str” port=”num” )&lt;br /&gt;
Ilyen Tag-ekkel kell felsorolni a rendszerhez kapcsolódó adatbázisokat, az id tetszőleges, de egyedi kell legyen.&lt;br /&gt;
torque&lt;br /&gt;
A Torque modul konfigurációját tartalmazza a szabványnak megfelelően.2&lt;br /&gt;
Több adatbázis esetén ez a rész nem szükséges, csak a ha-jdbc.&lt;br /&gt;
&amp;lt;applicationRoot&amp;gt;.&amp;lt;/applicationRoot&amp;gt;&lt;br /&gt;
Az alkalmazás gyökere, mindig “.” az értéke.&lt;br /&gt;
defaults&lt;br /&gt;
Alapértelmezett értékek, konfigurációs beállítások.&lt;br /&gt;
pool&lt;br /&gt;
Szálakkal kapcsolatos beállítások.&lt;br /&gt;
&amp;lt;maxWait&amp;gt;10000&amp;lt;/maxWait&amp;gt;&lt;br /&gt;
Maximum várakozási idő, mielőtt egy kapcsolódás meghiúsulna (milliszekundum).&lt;br /&gt;
&amp;lt;maxIdle&amp;gt;20&amp;lt;/maxIdle&amp;gt;&lt;br /&gt;
Várakozó szálak maximális száma.&lt;br /&gt;
&amp;lt;maxActive&amp;gt;50&amp;lt;/maxActive&amp;gt;&lt;br /&gt;
Aktív szálak (kapcsolatok) maximális száma.&lt;br /&gt;
&amp;lt;timeBetweenEvictionRunsMillis&amp;gt;300000&amp;lt;/timeBetweenEvictionRunsMillis&amp;gt;&lt;br /&gt;
&amp;lt;minEvictableIdleTimeMillis&amp;gt;3600000&amp;lt;/minEvictableIdleTimeMillis&amp;gt;&lt;br /&gt;
connection&lt;br /&gt;
Az adatbázis kapcsolat beállításai.&lt;br /&gt;
driver&lt;br /&gt;
Az adatbáziskezelőhöz tartozó Java Driver.&lt;br /&gt;
MySQL: com.mysql.jdbc.Driver�PostgreSQL: org.postgresql.Driver&lt;br /&gt;
url&lt;br /&gt;
Az adatbáziskezelő JDBC URL-je.&lt;br /&gt;
MySQL: jdbc:mysql://host:port/adatbazisnev�PostgreSQL: jdbc:postgresql://host:port/adatbazisnev&lt;br /&gt;
user&lt;br /&gt;
Az adatbázishoz csatlakozó felhasználó neve.&lt;br /&gt;
password&lt;br /&gt;
Az adatbázishoz csatlakozó felhasználó jelszava.&lt;br /&gt;
database&lt;br /&gt;
Adatbázis tulajdonságai.&lt;br /&gt;
default&lt;br /&gt;
Az alapértelmezett adatbázis (logikai) neve&lt;br /&gt;
[az_előző_pontban_megadott_név]&lt;br /&gt;
adapter&lt;br /&gt;
Az adatbázist kezelő adapter neve, keresd a Torque dokumentációjában. Leggyakrabban a mysql vagy postgresql adaptereket használjuk.&lt;br /&gt;
dsfactory&lt;br /&gt;
DataSourceFactory - A Torque használja, javasolt az alább Factory használata.&lt;br /&gt;
[alapértelmezett_adatbazis_neve]&lt;br /&gt;
&amp;lt;factory&amp;gt;org.apache.torque.dsfactory.SharedPoolDataSourceFactory&amp;lt;/factory&amp;gt;&lt;br /&gt;
&amp;lt;idbroker.clever.quantity&amp;gt;true&amp;lt;/idbroker.clever.quantity&amp;gt;&lt;br /&gt;
&amp;lt;manager.useCache&amp;gt;true&amp;lt;/manager.useCache&amp;gt;&lt;br /&gt;
ha-jdbc (Attríbutuma: cluster=”str” )&lt;br /&gt;
Több adatbázis együttes kezelésekor szükséges, a cluster paraméter egy tetszőleges logikai név, pl.: SiwenoidDbCluster. Egy adatbázis esetén ez a rész nem szükséges, de ha ez nincs beállítva, akkor a torque résznek kell megfelelőnek lennie.&lt;br /&gt;
&amp;lt;sync id=&amp;quot;tetszőleges&amp;quot; class=&amp;quot;hu.siwena.services.database.synchronization.CustomDifferentialSynchronizationStrategy&amp;quot;/&amp;gt;&lt;br /&gt;
Adatbázisok szinkronizálását végző osztály konfigurálása.&lt;br /&gt;
cluster&lt;br /&gt;
Az adatbázis cluster konfigurálása.&lt;br /&gt;
Attribútumai:&lt;br /&gt;
balancer=&amp;quot;simple&amp;quot;&lt;br /&gt;
default-sync=&amp;quot;fentebb megadott sync id attribútumának értéke&amp;quot;&lt;br /&gt;
dialect=&amp;quot;mysql&amp;quot; lehet pl. postgresql is, lásd a HA-JDBC dokumentációját 3&lt;br /&gt;
meta-data-cache=&amp;quot;lazy&amp;quot;&lt;br /&gt;
transaction-mode=&amp;quot;parallel&amp;quot;&lt;br /&gt;
max-threads=&amp;quot;5&amp;quot;&lt;br /&gt;
auto-activate-schedule=&amp;quot;0 0/1 * * * ?&amp;quot;&lt;br /&gt;
Az adatbázisok aktiválását végző Cron ütemező futási idő konfigurációja.4&lt;br /&gt;
failure-detect-schedule=&amp;quot;0/15 * * * * ?&amp;quot;&lt;br /&gt;
Az adatbázisok kiesését vizsgáló Cron ütemező futási idő konfigurációja.4&lt;br /&gt;
Gyerek elemek:&lt;br /&gt;
database (Attribútuma: id=”a fentebb megadott id-k egyike” )&lt;br /&gt;
Egy-egy adatbázist reprezentáló elem.&lt;br /&gt;
driver&lt;br /&gt;
Lásd torque.defaults.connection.driver.&lt;br /&gt;
url&lt;br /&gt;
Lásd torque.defaults.connection.url.&lt;br /&gt;
user&lt;br /&gt;
Lásd torque.defaults.connection.user.&lt;br /&gt;
password&lt;br /&gt;
Lásd torque.defaults.connection.password.&lt;br /&gt;
database&lt;br /&gt;
....&lt;br /&gt;
DataPointService&lt;br /&gt;
Az adatpontokkal kapcsolatos szervíz konfigurációja, ez definiálja a használandó adatpont kezelőket is.&lt;br /&gt;
rootcontainername&lt;br /&gt;
A gyökér konténer neve, alapértelmezetten root.&lt;br /&gt;
systemcontainername&lt;br /&gt;
A rendszer konténer neve, alapértelmezetten system.&lt;br /&gt;
pre-cache&lt;br /&gt;
Töltse-e be az adatpontokat és gyerek listáikat automatikusan a cache-be induláskor. Az alapértelmezett érték: false. Lehetséges értékek: true vagy false.&lt;br /&gt;
import-memory-opts&lt;br /&gt;
Az adatpont importáló alkalmazás indításakor használandó memóriaszabályzó paraméter. Pl. -Xmx512m azt jelenti, hogy az alkalmazás max. 512 MB memóriát fog tudni használni.&lt;br /&gt;
Az alapértelmezett érték: -Xmx512m.&lt;br /&gt;
datapointhandlers&lt;br /&gt;
Adatpontkezelők felsorolása. Minden “item” Tag-be egy-egy kezelő teljes (minősített) nevét kell írni.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
Például:&lt;br /&gt;
&amp;lt;item&amp;gt;hu.siwena.services.datapoint.handlers.SystemHandler&amp;lt;/item&amp;gt;&lt;br /&gt;
&amp;lt;item&amp;gt;hu.siwena.services.datapoint.handlers.AlgorexHandler&amp;lt;/item&amp;gt;&lt;br /&gt;
SystemHandler&lt;br /&gt;
A rendszer-adatpontokat kezelő osztály konfigurációja.&lt;br /&gt;
type (Attribútumai: id=”adatpont_típus” )&lt;br /&gt;
Az adatpont típus lehetséges értékei:&lt;br /&gt;
1 szerver&lt;br /&gt;
2 adatbázis&lt;br /&gt;
16 kliens számláló&lt;br /&gt;
17 kliens&lt;br /&gt;
Az elem tartalma egy eseménykategória azonosítója, ebbe a kategóriába fog tartozni az a treatment, amellyel az adatbont normálistól eltérő állapotai kerülnek.&lt;br /&gt;
AlgorexHandler és AlgorexMultiportHandler&lt;br /&gt;
Az Algorex protokollal operáló adatpontok kezelője, illetve ennek a Hot-standby párja konfigurációi.&lt;br /&gt;
sockettimeout&lt;br /&gt;
Az alközponthoz kapcsolódás timeout-ja.&lt;br /&gt;
socketkeepalive&lt;br /&gt;
Az életjel telegram értéke, minden esetben 0x01.&lt;br /&gt;
BACnetHandler&lt;br /&gt;
A BACnet protokollal kommunikáló adatpontok kezelőjének konfigurációja.&lt;br /&gt;
disabled-types&lt;br /&gt;
Az import során az itt felsorolt típusú elemek figyelmen kívül hagyja.&lt;br /&gt;
item&lt;br /&gt;
Értéke a tiltandó típus neve, pl.: EO_FI_ZoneManualElem&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
CerbanHandler és CerbanMultiportHandler&lt;br /&gt;
A Cerban protokollal működő adatpontok kezelője, illetve ennek a Hot-standby párja konfigurációi.&lt;br /&gt;
sockettimeout&lt;br /&gt;
Az alközponthoz kapcsolódás timeout-ja.&lt;br /&gt;
socketkeepalive&lt;br /&gt;
Az életjel telegram értéke, minden esetben 0x01.&lt;br /&gt;
SIAHandler&lt;br /&gt;
A SIA protokolhoz tartozó adatpontok kezelőjének konfigurációja.&lt;br /&gt;
Egyelőre nincs konfigurációs lehetőség.&lt;br /&gt;
RmiService&lt;br /&gt;
A szerver-kliens kapcsolatokat kezelő szervíz konfigurációja.&lt;br /&gt;
port&lt;br /&gt;
A kapcsolatokat fogadó (Registry) port száma. Alapértelmezett értéke: 1899.&lt;br /&gt;
sessiontimeout&lt;br /&gt;
A kapcsolatok elévülési ideje, ennyi (milliszekundum) inaktivitás után bontja a kapcsolatot a szerver. Alapértelmezetten: 6000.&lt;br /&gt;
sessioncheckperiod&lt;br /&gt;
A kapcsolatok elévülését ellenőrző ütemező periódusideje. Alapértelmezetten: 5000.&lt;br /&gt;
clientcount&lt;br /&gt;
Az egyszerre csatlakozott kliensek elvárt száma. &lt;br /&gt;
separate-acknowledge&lt;br /&gt;
Lehetséges értékei: true vagy false, alapértelmezetten: true.&lt;br /&gt;
Igaz értéke esetén minden kliensen külön-külön le kell nyugtázni egy új eseményt, hamis értéke esetén valamely kliens nyugtája az összes kliensen nyugtázza az eseményt.&lt;br /&gt;
pre-cache&lt;br /&gt;
Lehetséges értékei: true vagy false, alapértelmezetten: false.&lt;br /&gt;
Igaz értéke esetén induláskor betölti cache-be a treatmentek és parancsok listáját.&lt;br /&gt;
enabled-locales&lt;br /&gt;
Az engedélyezett nyelvek kódjainak felsorolása. Alapértelmezetten: en és hu.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
event-log&lt;br /&gt;
Eseménymemóriával kapcsolatos konfiguráció. (Opcionális)&lt;br /&gt;
limit&lt;br /&gt;
Az eseménymemória mérethatára, ez felett kerül archiválásra. Alapértelmezetten: 50000.&lt;br /&gt;
starttime&lt;br /&gt;
Az eseménymemóri vizsgálatának kezdete naponta (óra:perc). Alapértelmezetten a szerver indulásakor indul az ütemezés.&lt;br /&gt;
AuthenticationService&lt;br /&gt;
A felhasználók kezelésével kapcsolatos szervíz konfigurációja.&lt;br /&gt;
administrator&lt;br /&gt;
Az adminisztrátor felhasználóra vonatkozó információk, amennyiben a felhasználó még nem létezik, ezekkel az adatokkal fogja létrehozni. A belépési információkat (felhasználónév, jelszó) első indításkor fogja kérni a szerver.&lt;br /&gt;
firstname&lt;br /&gt;
lastname&lt;br /&gt;
email&lt;br /&gt;
language&lt;br /&gt;
A felhasználói felület nyelvének kódja.&lt;br /&gt;
ScriptService&lt;br /&gt;
A scriptek futtatásáért felelős szervíz konfigurációja.&lt;br /&gt;
categories&lt;br /&gt;
Script kategóriák felsorolása, lásd a Siwenoid Scripting dokumentációt.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
apis&lt;br /&gt;
Script API-k felsorolása, lásd a Siwenoid Scripting dokumentációt.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
SignalService&lt;br /&gt;
A Hot-standby megoldást implementáló szervíz konfigurációja, illetve a csatlakó JGroups5 modul beállításai. A következő 3 tulajdonság egyikének, illetve a server-list elemnek kell benne lennie:&lt;br /&gt;
1) jchannel:file&lt;br /&gt;
A csatorna konfiguriációját5 tartalmazó fájl útvonala.&lt;br /&gt;
2) jchannel:simple&lt;br /&gt;
A csatorna egyszerű konfigurációját5 tartalmazó szöveg.&lt;br /&gt;
3) jchannel:config&lt;br /&gt;
A csatorna XML konfigurációja.5&lt;br /&gt;
server-list&lt;br /&gt;
Szerverek listáját felsoroló rész.&lt;br /&gt;
server (Attribútuma: priority=”num” )&lt;br /&gt;
Egy szervert reprezentáló elem. A priority attribútum a szerver prioritását határozza meg, a nagyobb a fontosabb.&lt;br /&gt;
host&lt;br /&gt;
A szerver csatorna host címe.&lt;br /&gt;
port&lt;br /&gt;
A szerver csatorna portja.&lt;br /&gt;
License&lt;br /&gt;
A Licensszel kapcsolatos konfiguráció.&lt;br /&gt;
stick-serial&lt;br /&gt;
A mellékelt CodeMeter USB kulcs sorozatszáma.&lt;br /&gt;
firmcode&lt;br /&gt;
A gyártó kódja: 101459.&lt;br /&gt;
productcode&lt;br /&gt;
A termék kódja: 10.&lt;br /&gt;
SocketService&lt;br /&gt;
Az Algorex adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
BACnetCommunicationService&lt;br /&gt;
A BACnet adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
timeout&lt;br /&gt;
A BACnet-es kapcsolat timeout-ja. (milliszekundum)&lt;br /&gt;
Alapértelmezett: 5000.&lt;br /&gt;
instancenumber&lt;br /&gt;
A szerver BACnet azonosítója, alapértelmezetten: 100.&lt;br /&gt;
address&lt;br /&gt;
Broadcast cím, erre küldi ki a központokat kereső üzeneteket a szerver.&lt;br /&gt;
Alapértelmezetten: 255.255.255.255&lt;br /&gt;
localbindaddress&lt;br /&gt;
A helyi host címe, alapértelmezetten: 0.0.0.0&lt;br /&gt;
port&lt;br /&gt;
A BACnet port, alapértelmezetten: 47808.&lt;br /&gt;
CerbanSocketService&lt;br /&gt;
A Cerban adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
SIACommunicationService&lt;br /&gt;
A SIA adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
AndroidService&lt;br /&gt;
Az Android klienseket kezelő szervíz konfigurációja.&lt;br /&gt;
bindaddress&lt;br /&gt;
A helyi host címe, alapértelmezetten a lokális host.&lt;br /&gt;
listenport&lt;br /&gt;
A kapcsolatokat váró port száma, alapértelmezetten: 5559.&lt;br /&gt;
maxmapsize&lt;br /&gt;
A térképek maximális mérete (szélesség és magasság), alapértelmezetten: 1024.&lt;br /&gt;
IECService&lt;br /&gt;
Az IEC101 protokollal kapcsolatos szervíz konfigurációja.&lt;br /&gt;
configuration&lt;br /&gt;
A szükséges beállításokat tartalmazó fájl elérési útja.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
1 log4J XML konfiguráció: &lt;br /&gt;
http://logging.apache.org/log4j/1.2/apidocs/org/apache/log4j/xml/DOMConfigurator.html&lt;br /&gt;
&lt;br /&gt;
2 Torque konfiguráció: &lt;br /&gt;
http://db.apache.org/torque/releases/torque-3.3/runtime/reference/initialisation-configuration.html&lt;br /&gt;
Az itt leírtak a Properties fájlból való konfigurációra vonatkoznak, mely könnyedén átfordítható XML-lé: &lt;br /&gt;
A tulajdonságokban szereplő pontok az XML-ben egy-egy gyerek elemet jelentenek, pl.:&lt;br /&gt;
torque.default.connection.driver &amp;lt;&amp;gt; &amp;lt;torque&amp;gt;&amp;lt;defaults&amp;gt;&amp;lt;connection&amp;gt;&amp;lt;driver&amp;gt;...&amp;lt;/driver&amp;gt;&amp;lt;/conn...&lt;br /&gt;
&lt;br /&gt;
3 HA-JDBC dialektusok:&lt;br /&gt;
http://ha-jdbc.sourceforge.net/doc.html#dialect&lt;br /&gt;
&lt;br /&gt;
4 Cron ütemező konfigurálása:&lt;br /&gt;
http://www.quartz-scheduler.org/docs/tutorials/crontrigger.html&lt;br /&gt;
&lt;br /&gt;
5 JGroups csatorna konfiguráció:&lt;br /&gt;
http://www.jgroups.org/manual/html/user-advanced.html#d0e2444&lt;br /&gt;
Protokolok listája:&lt;br /&gt;
http://www.jgroups.org/manual/html/protlist.html&lt;br /&gt;
Egyéb információ:&lt;br /&gt;
http://community.jboss.org/wiki/JGroups&lt;/div&gt;</summary>
		<author><name>91.82.214.70</name></author>
	</entry>
	<entry>
		<id>https://wiki.siwenoid.com/index.php?title=Config_file_parameters&amp;diff=400</id>
		<title>Config file parameters</title>
		<link rel="alternate" type="text/html" href="https://wiki.siwenoid.com/index.php?title=Config_file_parameters&amp;diff=400"/>
		<updated>2010-09-25T07:52:58Z</updated>

		<summary type="html">&lt;p&gt;91.82.214.70: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Szerver parancssori paraméterei&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
A szerver indításához minimálisan a &#039;&#039;&#039;java -jar Siwenoid.jar&#039;&#039;&#039; parancs szükséges. A további paramétereket a &#039;&#039;&#039;java&#039;&#039;&#039; és a &#039;&#039;&#039;-jar&#039;&#039;&#039; közé kell megadni. Főbb beállítási lehetőségek:&lt;br /&gt;
*-Dsiwenoid.registry.port=1099&amp;lt;br /&amp;gt;A szerver saját magát menedzselő RMI portja, ezen keresztül tudja például ellenőrizni induláskor, hogy fut-e már másik példány a számítógépen. Alapértelmezetten: 1099.&lt;br /&gt;
*-Dhajdbc.home=..path..&amp;lt;br /&amp;gt;Ezzel a beállítással lehet befolyásolni, hogy a HA-JDBC modul hol keresse a konfigurációs fájlját. (Általában nem kell megváltoztatni az alapértelmezettet.)&lt;br /&gt;
*-Xms128m&amp;lt;br /&amp;gt;A szerver induláskor ennyi memóriát foglaljon le.&lt;br /&gt;
*-Xmx1024m&amp;lt;br /&amp;gt;A szerver a futása során legfeljebb ennyi memóriát használhat. Az 1024m azt jelenti, hogy maximum 1024 MB. A javasolt beállítás kisebb rendszereknél -Xmx512m nagyobbaknál -Xmx1024m.&lt;br /&gt;
&lt;br /&gt;
További parancssori argumentumok (a parancs után kell írni őket szóközzel elválasztva):&lt;br /&gt;
-start&lt;br /&gt;
Elindítja a szervert (ez az alapértelmezett).&lt;br /&gt;
-stop&lt;br /&gt;
Leállítja a futó szervert.&lt;br /&gt;
-restart&lt;br /&gt;
Újraindítja a futó szervert.&lt;br /&gt;
-version&lt;br /&gt;
Kiírja a szerver verziószámát.&lt;br /&gt;
&lt;br /&gt;
Szerver oldali XML konfiguráció:&lt;br /&gt;
&lt;br /&gt;
Siwenoid&lt;br /&gt;
Gyökér elem, az XML szabvány szempontjából fontos, minden dokumentumnak pontosan egy gyökere van.&lt;br /&gt;
Services&lt;br /&gt;
A szerver által használt szervízek sorrendhelyes felsorolása. Ez alatt minden egyes elem Tag-je a szervíz osztályának egyszerű neve, tartalma pedig az osztály teljes (minősített) neve. Pl.:&lt;br /&gt;
&amp;lt;CacheService&amp;gt;hu.siwena.services.cache.CacheService&amp;lt;/CacheService&amp;gt;&lt;br /&gt;
&amp;lt;DatabaseService&amp;gt;hu.siwena.services.database.DatabaseService&amp;lt;/DatabaseService&amp;gt;&lt;br /&gt;
...&lt;br /&gt;
LoggerService&lt;br /&gt;
A logolásért felelős szervíz konfigurációja, a log4J modulnak megfelelően.1 Legegyszerűbb konfigurációja például:&lt;br /&gt;
&amp;lt;log4j:configuration xmlns:log4j=&amp;quot;http://jakarta.apache.org/log4j/&amp;quot;&amp;gt;&lt;br /&gt;
		&amp;lt;appender name=&amp;quot;root_fileappender&amp;quot; class=&amp;quot;org.apache.log4j.DailyRollingFileAppender&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;File&amp;quot; value=&amp;quot;log/siwenoid.log&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;Append&amp;quot; value=&amp;quot;true&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;ImmediateFlush&amp;quot; value=&amp;quot;true&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;layout class=&amp;quot;org.apache.log4j.PatternLayout&amp;quot;&amp;gt;&lt;br /&gt;
		      		&amp;lt;param name=&amp;quot;ConversionPattern&amp;quot; value=&amp;quot;[%d] - %m%n&amp;quot;/&amp;gt;&lt;br /&gt;
 &amp;lt;/layout&amp;gt;&lt;br /&gt;
		 &amp;lt;/appender&amp;gt;&lt;br /&gt;
		&amp;lt;logger name=&amp;quot;hu.siwena&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;level value=&amp;quot;info&amp;quot;/&amp;gt;&lt;br /&gt;
			&amp;lt;appender-ref ref=&amp;quot;root_fileappender&amp;quot;/&amp;gt;&lt;br /&gt;
		&amp;lt;/logger&amp;gt;&lt;br /&gt;
		&amp;lt;appender name=&amp;quot;dbappender&amp;quot; class=&amp;quot;hu.siwena.services.database.synchronization.DatabaseErrorAppender&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;layout class=&amp;quot;org.apache.log4j.PatternLayout&amp;quot;&amp;gt;&lt;br /&gt;
				&amp;lt;param name=&amp;quot;ConversionPattern&amp;quot; value=&amp;quot;%m%n&amp;quot;/&amp;gt; 				&lt;br /&gt;
			&amp;lt;/layout&amp;gt;&lt;br /&gt;
		&amp;lt;/appender&amp;gt;&lt;br /&gt;
		&amp;lt;logger name=&amp;quot;net.sf.hajdbc&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;level value=&amp;quot;debug&amp;quot;/&amp;gt;&lt;br /&gt;
			&amp;lt;appender-ref ref=&amp;quot;dbappender&amp;quot;/&amp;gt;&lt;br /&gt;
		&amp;lt;/logger&amp;gt;&lt;br /&gt;
		 &amp;lt;root&amp;gt;&lt;br /&gt;
		 	 &amp;lt;level value=&amp;quot;error&amp;quot;/&amp;gt;&lt;br /&gt;
		  &amp;lt;/root&amp;gt;&lt;br /&gt;
	&amp;lt;/log4j:configuration&amp;gt;&lt;br /&gt;
DatabaseService&lt;br /&gt;
Az adatbázist kezelő szervíz konfigurációja.&lt;br /&gt;
database (Attribútumok: id=”str” host=”str” port=”num” )&lt;br /&gt;
Ilyen Tag-ekkel kell felsorolni a rendszerhez kapcsolódó adatbázisokat, az id tetszőleges, de egyedi kell legyen.&lt;br /&gt;
torque&lt;br /&gt;
A Torque modul konfigurációját tartalmazza a szabványnak megfelelően.2&lt;br /&gt;
Több adatbázis esetén ez a rész nem szükséges, csak a ha-jdbc.&lt;br /&gt;
&amp;lt;applicationRoot&amp;gt;.&amp;lt;/applicationRoot&amp;gt;&lt;br /&gt;
Az alkalmazás gyökere, mindig “.” az értéke.&lt;br /&gt;
defaults&lt;br /&gt;
Alapértelmezett értékek, konfigurációs beállítások.&lt;br /&gt;
pool&lt;br /&gt;
Szálakkal kapcsolatos beállítások.&lt;br /&gt;
&amp;lt;maxWait&amp;gt;10000&amp;lt;/maxWait&amp;gt;&lt;br /&gt;
Maximum várakozási idő, mielőtt egy kapcsolódás meghiúsulna (milliszekundum).&lt;br /&gt;
&amp;lt;maxIdle&amp;gt;20&amp;lt;/maxIdle&amp;gt;&lt;br /&gt;
Várakozó szálak maximális száma.&lt;br /&gt;
&amp;lt;maxActive&amp;gt;50&amp;lt;/maxActive&amp;gt;&lt;br /&gt;
Aktív szálak (kapcsolatok) maximális száma.&lt;br /&gt;
&amp;lt;timeBetweenEvictionRunsMillis&amp;gt;300000&amp;lt;/timeBetweenEvictionRunsMillis&amp;gt;&lt;br /&gt;
&amp;lt;minEvictableIdleTimeMillis&amp;gt;3600000&amp;lt;/minEvictableIdleTimeMillis&amp;gt;&lt;br /&gt;
connection&lt;br /&gt;
Az adatbázis kapcsolat beállításai.&lt;br /&gt;
driver&lt;br /&gt;
Az adatbáziskezelőhöz tartozó Java Driver.&lt;br /&gt;
MySQL: com.mysql.jdbc.Driver�PostgreSQL: org.postgresql.Driver&lt;br /&gt;
url&lt;br /&gt;
Az adatbáziskezelő JDBC URL-je.&lt;br /&gt;
MySQL: jdbc:mysql://host:port/adatbazisnev�PostgreSQL: jdbc:postgresql://host:port/adatbazisnev&lt;br /&gt;
user&lt;br /&gt;
Az adatbázishoz csatlakozó felhasználó neve.&lt;br /&gt;
password&lt;br /&gt;
Az adatbázishoz csatlakozó felhasználó jelszava.&lt;br /&gt;
database&lt;br /&gt;
Adatbázis tulajdonságai.&lt;br /&gt;
default&lt;br /&gt;
Az alapértelmezett adatbázis (logikai) neve&lt;br /&gt;
[az_előző_pontban_megadott_név]&lt;br /&gt;
adapter&lt;br /&gt;
Az adatbázist kezelő adapter neve, keresd a Torque dokumentációjában. Leggyakrabban a mysql vagy postgresql adaptereket használjuk.&lt;br /&gt;
dsfactory&lt;br /&gt;
DataSourceFactory - A Torque használja, javasolt az alább Factory használata.&lt;br /&gt;
[alapértelmezett_adatbazis_neve]&lt;br /&gt;
&amp;lt;factory&amp;gt;org.apache.torque.dsfactory.SharedPoolDataSourceFactory&amp;lt;/factory&amp;gt;&lt;br /&gt;
&amp;lt;idbroker.clever.quantity&amp;gt;true&amp;lt;/idbroker.clever.quantity&amp;gt;&lt;br /&gt;
&amp;lt;manager.useCache&amp;gt;true&amp;lt;/manager.useCache&amp;gt;&lt;br /&gt;
ha-jdbc (Attríbutuma: cluster=”str” )&lt;br /&gt;
Több adatbázis együttes kezelésekor szükséges, a cluster paraméter egy tetszőleges logikai név, pl.: SiwenoidDbCluster. Egy adatbázis esetén ez a rész nem szükséges, de ha ez nincs beállítva, akkor a torque résznek kell megfelelőnek lennie.&lt;br /&gt;
&amp;lt;sync id=&amp;quot;tetszőleges&amp;quot; class=&amp;quot;hu.siwena.services.database.synchronization.CustomDifferentialSynchronizationStrategy&amp;quot;/&amp;gt;&lt;br /&gt;
Adatbázisok szinkronizálását végző osztály konfigurálása.&lt;br /&gt;
cluster&lt;br /&gt;
Az adatbázis cluster konfigurálása.&lt;br /&gt;
Attribútumai:&lt;br /&gt;
balancer=&amp;quot;simple&amp;quot;&lt;br /&gt;
default-sync=&amp;quot;fentebb megadott sync id attribútumának értéke&amp;quot;&lt;br /&gt;
dialect=&amp;quot;mysql&amp;quot; lehet pl. postgresql is, lásd a HA-JDBC dokumentációját 3&lt;br /&gt;
meta-data-cache=&amp;quot;lazy&amp;quot;&lt;br /&gt;
transaction-mode=&amp;quot;parallel&amp;quot;&lt;br /&gt;
max-threads=&amp;quot;5&amp;quot;&lt;br /&gt;
auto-activate-schedule=&amp;quot;0 0/1 * * * ?&amp;quot;&lt;br /&gt;
Az adatbázisok aktiválását végző Cron ütemező futási idő konfigurációja.4&lt;br /&gt;
failure-detect-schedule=&amp;quot;0/15 * * * * ?&amp;quot;&lt;br /&gt;
Az adatbázisok kiesését vizsgáló Cron ütemező futási idő konfigurációja.4&lt;br /&gt;
Gyerek elemek:&lt;br /&gt;
database (Attribútuma: id=”a fentebb megadott id-k egyike” )&lt;br /&gt;
Egy-egy adatbázist reprezentáló elem.&lt;br /&gt;
driver&lt;br /&gt;
Lásd torque.defaults.connection.driver.&lt;br /&gt;
url&lt;br /&gt;
Lásd torque.defaults.connection.url.&lt;br /&gt;
user&lt;br /&gt;
Lásd torque.defaults.connection.user.&lt;br /&gt;
password&lt;br /&gt;
Lásd torque.defaults.connection.password.&lt;br /&gt;
database&lt;br /&gt;
....&lt;br /&gt;
DataPointService&lt;br /&gt;
Az adatpontokkal kapcsolatos szervíz konfigurációja, ez definiálja a használandó adatpont kezelőket is.&lt;br /&gt;
rootcontainername&lt;br /&gt;
A gyökér konténer neve, alapértelmezetten root.&lt;br /&gt;
systemcontainername&lt;br /&gt;
A rendszer konténer neve, alapértelmezetten system.&lt;br /&gt;
pre-cache&lt;br /&gt;
Töltse-e be az adatpontokat és gyerek listáikat automatikusan a cache-be induláskor. Az alapértelmezett érték: false. Lehetséges értékek: true vagy false.&lt;br /&gt;
import-memory-opts&lt;br /&gt;
Az adatpont importáló alkalmazás indításakor használandó memóriaszabályzó paraméter. Pl. -Xmx512m azt jelenti, hogy az alkalmazás max. 512 MB memóriát fog tudni használni.&lt;br /&gt;
Az alapértelmezett érték: -Xmx512m.&lt;br /&gt;
datapointhandlers&lt;br /&gt;
Adatpontkezelők felsorolása. Minden “item” Tag-be egy-egy kezelő teljes (minősített) nevét kell írni.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
Például:&lt;br /&gt;
&amp;lt;item&amp;gt;hu.siwena.services.datapoint.handlers.SystemHandler&amp;lt;/item&amp;gt;&lt;br /&gt;
&amp;lt;item&amp;gt;hu.siwena.services.datapoint.handlers.AlgorexHandler&amp;lt;/item&amp;gt;&lt;br /&gt;
SystemHandler&lt;br /&gt;
A rendszer-adatpontokat kezelő osztály konfigurációja.&lt;br /&gt;
type (Attribútumai: id=”adatpont_típus” )&lt;br /&gt;
Az adatpont típus lehetséges értékei:&lt;br /&gt;
1 szerver&lt;br /&gt;
2 adatbázis&lt;br /&gt;
16 kliens számláló&lt;br /&gt;
17 kliens&lt;br /&gt;
Az elem tartalma egy eseménykategória azonosítója, ebbe a kategóriába fog tartozni az a treatment, amellyel az adatbont normálistól eltérő állapotai kerülnek.&lt;br /&gt;
AlgorexHandler és AlgorexMultiportHandler&lt;br /&gt;
Az Algorex protokollal operáló adatpontok kezelője, illetve ennek a Hot-standby párja konfigurációi.&lt;br /&gt;
sockettimeout&lt;br /&gt;
Az alközponthoz kapcsolódás timeout-ja.&lt;br /&gt;
socketkeepalive&lt;br /&gt;
Az életjel telegram értéke, minden esetben 0x01.&lt;br /&gt;
BACnetHandler&lt;br /&gt;
A BACnet protokollal kommunikáló adatpontok kezelőjének konfigurációja.&lt;br /&gt;
disabled-types&lt;br /&gt;
Az import során az itt felsorolt típusú elemek figyelmen kívül hagyja.&lt;br /&gt;
item&lt;br /&gt;
Értéke a tiltandó típus neve, pl.: EO_FI_ZoneManualElem&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
CerbanHandler és CerbanMultiportHandler&lt;br /&gt;
A Cerban protokollal működő adatpontok kezelője, illetve ennek a Hot-standby párja konfigurációi.&lt;br /&gt;
sockettimeout&lt;br /&gt;
Az alközponthoz kapcsolódás timeout-ja.&lt;br /&gt;
socketkeepalive&lt;br /&gt;
Az életjel telegram értéke, minden esetben 0x01.&lt;br /&gt;
SIAHandler&lt;br /&gt;
A SIA protokolhoz tartozó adatpontok kezelőjének konfigurációja.&lt;br /&gt;
Egyelőre nincs konfigurációs lehetőség.&lt;br /&gt;
RmiService&lt;br /&gt;
A szerver-kliens kapcsolatokat kezelő szervíz konfigurációja.&lt;br /&gt;
port&lt;br /&gt;
A kapcsolatokat fogadó (Registry) port száma. Alapértelmezett értéke: 1899.&lt;br /&gt;
sessiontimeout&lt;br /&gt;
A kapcsolatok elévülési ideje, ennyi (milliszekundum) inaktivitás után bontja a kapcsolatot a szerver. Alapértelmezetten: 6000.&lt;br /&gt;
sessioncheckperiod&lt;br /&gt;
A kapcsolatok elévülését ellenőrző ütemező periódusideje. Alapértelmezetten: 5000.&lt;br /&gt;
clientcount&lt;br /&gt;
Az egyszerre csatlakozott kliensek elvárt száma. &lt;br /&gt;
separate-acknowledge&lt;br /&gt;
Lehetséges értékei: true vagy false, alapértelmezetten: true.&lt;br /&gt;
Igaz értéke esetén minden kliensen külön-külön le kell nyugtázni egy új eseményt, hamis értéke esetén valamely kliens nyugtája az összes kliensen nyugtázza az eseményt.&lt;br /&gt;
pre-cache&lt;br /&gt;
Lehetséges értékei: true vagy false, alapértelmezetten: false.&lt;br /&gt;
Igaz értéke esetén induláskor betölti cache-be a treatmentek és parancsok listáját.&lt;br /&gt;
enabled-locales&lt;br /&gt;
Az engedélyezett nyelvek kódjainak felsorolása. Alapértelmezetten: en és hu.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
event-log&lt;br /&gt;
Eseménymemóriával kapcsolatos konfiguráció. (Opcionális)&lt;br /&gt;
limit&lt;br /&gt;
Az eseménymemória mérethatára, ez felett kerül archiválásra. Alapértelmezetten: 50000.&lt;br /&gt;
starttime&lt;br /&gt;
Az eseménymemóri vizsgálatának kezdete naponta (óra:perc). Alapértelmezetten a szerver indulásakor indul az ütemezés.&lt;br /&gt;
AuthenticationService&lt;br /&gt;
A felhasználók kezelésével kapcsolatos szervíz konfigurációja.&lt;br /&gt;
administrator&lt;br /&gt;
Az adminisztrátor felhasználóra vonatkozó információk, amennyiben a felhasználó még nem létezik, ezekkel az adatokkal fogja létrehozni. A belépési információkat (felhasználónév, jelszó) első indításkor fogja kérni a szerver.&lt;br /&gt;
firstname&lt;br /&gt;
lastname&lt;br /&gt;
email&lt;br /&gt;
language&lt;br /&gt;
A felhasználói felület nyelvének kódja.&lt;br /&gt;
ScriptService&lt;br /&gt;
A scriptek futtatásáért felelős szervíz konfigurációja.&lt;br /&gt;
categories&lt;br /&gt;
Script kategóriák felsorolása, lásd a Siwenoid Scripting dokumentációt.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
apis&lt;br /&gt;
Script API-k felsorolása, lásd a Siwenoid Scripting dokumentációt.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
SignalService&lt;br /&gt;
A Hot-standby megoldást implementáló szervíz konfigurációja, illetve a csatlakó JGroups5 modul beállításai. A következő 3 tulajdonság egyikének, illetve a server-list elemnek kell benne lennie:&lt;br /&gt;
1) jchannel:file&lt;br /&gt;
A csatorna konfiguriációját5 tartalmazó fájl útvonala.&lt;br /&gt;
2) jchannel:simple&lt;br /&gt;
A csatorna egyszerű konfigurációját5 tartalmazó szöveg.&lt;br /&gt;
3) jchannel:config&lt;br /&gt;
A csatorna XML konfigurációja.5&lt;br /&gt;
server-list&lt;br /&gt;
Szerverek listáját felsoroló rész.&lt;br /&gt;
server (Attribútuma: priority=”num” )&lt;br /&gt;
Egy szervert reprezentáló elem. A priority attribútum a szerver prioritását határozza meg, a nagyobb a fontosabb.&lt;br /&gt;
host&lt;br /&gt;
A szerver csatorna host címe.&lt;br /&gt;
port&lt;br /&gt;
A szerver csatorna portja.&lt;br /&gt;
License&lt;br /&gt;
A Licensszel kapcsolatos konfiguráció.&lt;br /&gt;
stick-serial&lt;br /&gt;
A mellékelt CodeMeter USB kulcs sorozatszáma.&lt;br /&gt;
firmcode&lt;br /&gt;
A gyártó kódja: 101459.&lt;br /&gt;
productcode&lt;br /&gt;
A termék kódja: 10.&lt;br /&gt;
SocketService&lt;br /&gt;
Az Algorex adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
BACnetCommunicationService&lt;br /&gt;
A BACnet adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
timeout&lt;br /&gt;
A BACnet-es kapcsolat timeout-ja. (milliszekundum)&lt;br /&gt;
Alapértelmezett: 5000.&lt;br /&gt;
instancenumber&lt;br /&gt;
A szerver BACnet azonosítója, alapértelmezetten: 100.&lt;br /&gt;
address&lt;br /&gt;
Broadcast cím, erre küldi ki a központokat kereső üzeneteket a szerver.&lt;br /&gt;
Alapértelmezetten: 255.255.255.255&lt;br /&gt;
localbindaddress&lt;br /&gt;
A helyi host címe, alapértelmezetten: 0.0.0.0&lt;br /&gt;
port&lt;br /&gt;
A BACnet port, alapértelmezetten: 47808.&lt;br /&gt;
CerbanSocketService&lt;br /&gt;
A Cerban adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
SIACommunicationService&lt;br /&gt;
A SIA adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
AndroidService&lt;br /&gt;
Az Android klienseket kezelő szervíz konfigurációja.&lt;br /&gt;
bindaddress&lt;br /&gt;
A helyi host címe, alapértelmezetten a lokális host.&lt;br /&gt;
listenport&lt;br /&gt;
A kapcsolatokat váró port száma, alapértelmezetten: 5559.&lt;br /&gt;
maxmapsize&lt;br /&gt;
A térképek maximális mérete (szélesség és magasság), alapértelmezetten: 1024.&lt;br /&gt;
IECService&lt;br /&gt;
Az IEC101 protokollal kapcsolatos szervíz konfigurációja.&lt;br /&gt;
configuration&lt;br /&gt;
A szükséges beállításokat tartalmazó fájl elérési útja.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
1 log4J XML konfiguráció: &lt;br /&gt;
http://logging.apache.org/log4j/1.2/apidocs/org/apache/log4j/xml/DOMConfigurator.html&lt;br /&gt;
&lt;br /&gt;
2 Torque konfiguráció: &lt;br /&gt;
http://db.apache.org/torque/releases/torque-3.3/runtime/reference/initialisation-configuration.html&lt;br /&gt;
Az itt leírtak a Properties fájlból való konfigurációra vonatkoznak, mely könnyedén átfordítható XML-lé: &lt;br /&gt;
A tulajdonságokban szereplő pontok az XML-ben egy-egy gyerek elemet jelentenek, pl.:&lt;br /&gt;
torque.default.connection.driver &amp;lt;&amp;gt; &amp;lt;torque&amp;gt;&amp;lt;defaults&amp;gt;&amp;lt;connection&amp;gt;&amp;lt;driver&amp;gt;...&amp;lt;/driver&amp;gt;&amp;lt;/conn...&lt;br /&gt;
&lt;br /&gt;
3 HA-JDBC dialektusok:&lt;br /&gt;
http://ha-jdbc.sourceforge.net/doc.html#dialect&lt;br /&gt;
&lt;br /&gt;
4 Cron ütemező konfigurálása:&lt;br /&gt;
http://www.quartz-scheduler.org/docs/tutorials/crontrigger.html&lt;br /&gt;
&lt;br /&gt;
5 JGroups csatorna konfiguráció:&lt;br /&gt;
http://www.jgroups.org/manual/html/user-advanced.html#d0e2444&lt;br /&gt;
Protokolok listája:&lt;br /&gt;
http://www.jgroups.org/manual/html/protlist.html&lt;br /&gt;
Egyéb információ:&lt;br /&gt;
http://community.jboss.org/wiki/JGroups&lt;/div&gt;</summary>
		<author><name>91.82.214.70</name></author>
	</entry>
	<entry>
		<id>https://wiki.siwenoid.com/index.php?title=Config_file_parameters&amp;diff=399</id>
		<title>Config file parameters</title>
		<link rel="alternate" type="text/html" href="https://wiki.siwenoid.com/index.php?title=Config_file_parameters&amp;diff=399"/>
		<updated>2010-09-25T07:51:45Z</updated>

		<summary type="html">&lt;p&gt;91.82.214.70: &lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;&#039;&#039;&#039;Szerver parancssori paraméterei&#039;&#039;&#039;&lt;br /&gt;
&lt;br /&gt;
A szerver indításához minimálisan a &#039;&#039;&#039;java -jar Siwenoid.jar&#039;&#039;&#039; parancs szükséges. A további paramétereket a &#039;&#039;&#039;java&#039;&#039;&#039; és a &#039;&#039;&#039;-jar&#039;&#039;&#039; közé kell megadni. Főbb beállítási lehetőségek:&lt;br /&gt;
*-Dsiwenoid.registry.port=1099&lt;br /&gt;
A szerver saját magát menedzselő RMI portja, ezen keresztül tudja például ellenőrizni induláskor, hogy fut-e már másik példány a számítógépen. Alapértelmezetten: 1099.&lt;br /&gt;
*-Dhajdbc.home=..path..&lt;br /&gt;
Ezzel a beállítással lehet befolyásolni, hogy a HA-JDBC modul hol keresse a konfigurációs fájlját. (Általában nem kell megváltoztatni az alapértelmezettet.)&lt;br /&gt;
*-Xms128m&lt;br /&gt;
A szerver induláskor ennyi memóriát foglaljon le.&lt;br /&gt;
*-Xmx1024m&lt;br /&gt;
A szerver a futása során legfeljebb ennyi memóriát használhat. Az 1024m azt jelenti, hogy maximum 1024 MB. A javasolt beállítás kisebb rendszereknél -Xmx512m nagyobbaknál -Xmx1024m.&lt;br /&gt;
&lt;br /&gt;
További parancssori argumentumok (a parancs után kell írni őket szóközzel elválasztva):&lt;br /&gt;
-start&lt;br /&gt;
Elindítja a szervert (ez az alapértelmezett).&lt;br /&gt;
-stop&lt;br /&gt;
Leállítja a futó szervert.&lt;br /&gt;
-restart&lt;br /&gt;
Újraindítja a futó szervert.&lt;br /&gt;
-version&lt;br /&gt;
Kiírja a szerver verziószámát.&lt;br /&gt;
&lt;br /&gt;
Szerver oldali XML konfiguráció:&lt;br /&gt;
&lt;br /&gt;
Siwenoid&lt;br /&gt;
Gyökér elem, az XML szabvány szempontjából fontos, minden dokumentumnak pontosan egy gyökere van.&lt;br /&gt;
Services&lt;br /&gt;
A szerver által használt szervízek sorrendhelyes felsorolása. Ez alatt minden egyes elem Tag-je a szervíz osztályának egyszerű neve, tartalma pedig az osztály teljes (minősített) neve. Pl.:&lt;br /&gt;
&amp;lt;CacheService&amp;gt;hu.siwena.services.cache.CacheService&amp;lt;/CacheService&amp;gt;&lt;br /&gt;
&amp;lt;DatabaseService&amp;gt;hu.siwena.services.database.DatabaseService&amp;lt;/DatabaseService&amp;gt;&lt;br /&gt;
...&lt;br /&gt;
LoggerService&lt;br /&gt;
A logolásért felelős szervíz konfigurációja, a log4J modulnak megfelelően.1 Legegyszerűbb konfigurációja például:&lt;br /&gt;
&amp;lt;log4j:configuration xmlns:log4j=&amp;quot;http://jakarta.apache.org/log4j/&amp;quot;&amp;gt;&lt;br /&gt;
		&amp;lt;appender name=&amp;quot;root_fileappender&amp;quot; class=&amp;quot;org.apache.log4j.DailyRollingFileAppender&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;File&amp;quot; value=&amp;quot;log/siwenoid.log&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;Append&amp;quot; value=&amp;quot;true&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;ImmediateFlush&amp;quot; value=&amp;quot;true&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;layout class=&amp;quot;org.apache.log4j.PatternLayout&amp;quot;&amp;gt;&lt;br /&gt;
		      		&amp;lt;param name=&amp;quot;ConversionPattern&amp;quot; value=&amp;quot;[%d] - %m%n&amp;quot;/&amp;gt;&lt;br /&gt;
 &amp;lt;/layout&amp;gt;&lt;br /&gt;
		 &amp;lt;/appender&amp;gt;&lt;br /&gt;
		&amp;lt;logger name=&amp;quot;hu.siwena&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;level value=&amp;quot;info&amp;quot;/&amp;gt;&lt;br /&gt;
			&amp;lt;appender-ref ref=&amp;quot;root_fileappender&amp;quot;/&amp;gt;&lt;br /&gt;
		&amp;lt;/logger&amp;gt;&lt;br /&gt;
		&amp;lt;appender name=&amp;quot;dbappender&amp;quot; class=&amp;quot;hu.siwena.services.database.synchronization.DatabaseErrorAppender&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;layout class=&amp;quot;org.apache.log4j.PatternLayout&amp;quot;&amp;gt;&lt;br /&gt;
				&amp;lt;param name=&amp;quot;ConversionPattern&amp;quot; value=&amp;quot;%m%n&amp;quot;/&amp;gt; 				&lt;br /&gt;
			&amp;lt;/layout&amp;gt;&lt;br /&gt;
		&amp;lt;/appender&amp;gt;&lt;br /&gt;
		&amp;lt;logger name=&amp;quot;net.sf.hajdbc&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;level value=&amp;quot;debug&amp;quot;/&amp;gt;&lt;br /&gt;
			&amp;lt;appender-ref ref=&amp;quot;dbappender&amp;quot;/&amp;gt;&lt;br /&gt;
		&amp;lt;/logger&amp;gt;&lt;br /&gt;
		 &amp;lt;root&amp;gt;&lt;br /&gt;
		 	 &amp;lt;level value=&amp;quot;error&amp;quot;/&amp;gt;&lt;br /&gt;
		  &amp;lt;/root&amp;gt;&lt;br /&gt;
	&amp;lt;/log4j:configuration&amp;gt;&lt;br /&gt;
DatabaseService&lt;br /&gt;
Az adatbázist kezelő szervíz konfigurációja.&lt;br /&gt;
database (Attribútumok: id=”str” host=”str” port=”num” )&lt;br /&gt;
Ilyen Tag-ekkel kell felsorolni a rendszerhez kapcsolódó adatbázisokat, az id tetszőleges, de egyedi kell legyen.&lt;br /&gt;
torque&lt;br /&gt;
A Torque modul konfigurációját tartalmazza a szabványnak megfelelően.2&lt;br /&gt;
Több adatbázis esetén ez a rész nem szükséges, csak a ha-jdbc.&lt;br /&gt;
&amp;lt;applicationRoot&amp;gt;.&amp;lt;/applicationRoot&amp;gt;&lt;br /&gt;
Az alkalmazás gyökere, mindig “.” az értéke.&lt;br /&gt;
defaults&lt;br /&gt;
Alapértelmezett értékek, konfigurációs beállítások.&lt;br /&gt;
pool&lt;br /&gt;
Szálakkal kapcsolatos beállítások.&lt;br /&gt;
&amp;lt;maxWait&amp;gt;10000&amp;lt;/maxWait&amp;gt;&lt;br /&gt;
Maximum várakozási idő, mielőtt egy kapcsolódás meghiúsulna (milliszekundum).&lt;br /&gt;
&amp;lt;maxIdle&amp;gt;20&amp;lt;/maxIdle&amp;gt;&lt;br /&gt;
Várakozó szálak maximális száma.&lt;br /&gt;
&amp;lt;maxActive&amp;gt;50&amp;lt;/maxActive&amp;gt;&lt;br /&gt;
Aktív szálak (kapcsolatok) maximális száma.&lt;br /&gt;
&amp;lt;timeBetweenEvictionRunsMillis&amp;gt;300000&amp;lt;/timeBetweenEvictionRunsMillis&amp;gt;&lt;br /&gt;
&amp;lt;minEvictableIdleTimeMillis&amp;gt;3600000&amp;lt;/minEvictableIdleTimeMillis&amp;gt;&lt;br /&gt;
connection&lt;br /&gt;
Az adatbázis kapcsolat beállításai.&lt;br /&gt;
driver&lt;br /&gt;
Az adatbáziskezelőhöz tartozó Java Driver.&lt;br /&gt;
MySQL: com.mysql.jdbc.Driver�PostgreSQL: org.postgresql.Driver&lt;br /&gt;
url&lt;br /&gt;
Az adatbáziskezelő JDBC URL-je.&lt;br /&gt;
MySQL: jdbc:mysql://host:port/adatbazisnev�PostgreSQL: jdbc:postgresql://host:port/adatbazisnev&lt;br /&gt;
user&lt;br /&gt;
Az adatbázishoz csatlakozó felhasználó neve.&lt;br /&gt;
password&lt;br /&gt;
Az adatbázishoz csatlakozó felhasználó jelszava.&lt;br /&gt;
database&lt;br /&gt;
Adatbázis tulajdonságai.&lt;br /&gt;
default&lt;br /&gt;
Az alapértelmezett adatbázis (logikai) neve&lt;br /&gt;
[az_előző_pontban_megadott_név]&lt;br /&gt;
adapter&lt;br /&gt;
Az adatbázist kezelő adapter neve, keresd a Torque dokumentációjában. Leggyakrabban a mysql vagy postgresql adaptereket használjuk.&lt;br /&gt;
dsfactory&lt;br /&gt;
DataSourceFactory - A Torque használja, javasolt az alább Factory használata.&lt;br /&gt;
[alapértelmezett_adatbazis_neve]&lt;br /&gt;
&amp;lt;factory&amp;gt;org.apache.torque.dsfactory.SharedPoolDataSourceFactory&amp;lt;/factory&amp;gt;&lt;br /&gt;
&amp;lt;idbroker.clever.quantity&amp;gt;true&amp;lt;/idbroker.clever.quantity&amp;gt;&lt;br /&gt;
&amp;lt;manager.useCache&amp;gt;true&amp;lt;/manager.useCache&amp;gt;&lt;br /&gt;
ha-jdbc (Attríbutuma: cluster=”str” )&lt;br /&gt;
Több adatbázis együttes kezelésekor szükséges, a cluster paraméter egy tetszőleges logikai név, pl.: SiwenoidDbCluster. Egy adatbázis esetén ez a rész nem szükséges, de ha ez nincs beállítva, akkor a torque résznek kell megfelelőnek lennie.&lt;br /&gt;
&amp;lt;sync id=&amp;quot;tetszőleges&amp;quot; class=&amp;quot;hu.siwena.services.database.synchronization.CustomDifferentialSynchronizationStrategy&amp;quot;/&amp;gt;&lt;br /&gt;
Adatbázisok szinkronizálását végző osztály konfigurálása.&lt;br /&gt;
cluster&lt;br /&gt;
Az adatbázis cluster konfigurálása.&lt;br /&gt;
Attribútumai:&lt;br /&gt;
balancer=&amp;quot;simple&amp;quot;&lt;br /&gt;
default-sync=&amp;quot;fentebb megadott sync id attribútumának értéke&amp;quot;&lt;br /&gt;
dialect=&amp;quot;mysql&amp;quot; lehet pl. postgresql is, lásd a HA-JDBC dokumentációját 3&lt;br /&gt;
meta-data-cache=&amp;quot;lazy&amp;quot;&lt;br /&gt;
transaction-mode=&amp;quot;parallel&amp;quot;&lt;br /&gt;
max-threads=&amp;quot;5&amp;quot;&lt;br /&gt;
auto-activate-schedule=&amp;quot;0 0/1 * * * ?&amp;quot;&lt;br /&gt;
Az adatbázisok aktiválását végző Cron ütemező futási idő konfigurációja.4&lt;br /&gt;
failure-detect-schedule=&amp;quot;0/15 * * * * ?&amp;quot;&lt;br /&gt;
Az adatbázisok kiesését vizsgáló Cron ütemező futási idő konfigurációja.4&lt;br /&gt;
Gyerek elemek:&lt;br /&gt;
database (Attribútuma: id=”a fentebb megadott id-k egyike” )&lt;br /&gt;
Egy-egy adatbázist reprezentáló elem.&lt;br /&gt;
driver&lt;br /&gt;
Lásd torque.defaults.connection.driver.&lt;br /&gt;
url&lt;br /&gt;
Lásd torque.defaults.connection.url.&lt;br /&gt;
user&lt;br /&gt;
Lásd torque.defaults.connection.user.&lt;br /&gt;
password&lt;br /&gt;
Lásd torque.defaults.connection.password.&lt;br /&gt;
database&lt;br /&gt;
....&lt;br /&gt;
DataPointService&lt;br /&gt;
Az adatpontokkal kapcsolatos szervíz konfigurációja, ez definiálja a használandó adatpont kezelőket is.&lt;br /&gt;
rootcontainername&lt;br /&gt;
A gyökér konténer neve, alapértelmezetten root.&lt;br /&gt;
systemcontainername&lt;br /&gt;
A rendszer konténer neve, alapértelmezetten system.&lt;br /&gt;
pre-cache&lt;br /&gt;
Töltse-e be az adatpontokat és gyerek listáikat automatikusan a cache-be induláskor. Az alapértelmezett érték: false. Lehetséges értékek: true vagy false.&lt;br /&gt;
import-memory-opts&lt;br /&gt;
Az adatpont importáló alkalmazás indításakor használandó memóriaszabályzó paraméter. Pl. -Xmx512m azt jelenti, hogy az alkalmazás max. 512 MB memóriát fog tudni használni.&lt;br /&gt;
Az alapértelmezett érték: -Xmx512m.&lt;br /&gt;
datapointhandlers&lt;br /&gt;
Adatpontkezelők felsorolása. Minden “item” Tag-be egy-egy kezelő teljes (minősített) nevét kell írni.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
Például:&lt;br /&gt;
&amp;lt;item&amp;gt;hu.siwena.services.datapoint.handlers.SystemHandler&amp;lt;/item&amp;gt;&lt;br /&gt;
&amp;lt;item&amp;gt;hu.siwena.services.datapoint.handlers.AlgorexHandler&amp;lt;/item&amp;gt;&lt;br /&gt;
SystemHandler&lt;br /&gt;
A rendszer-adatpontokat kezelő osztály konfigurációja.&lt;br /&gt;
type (Attribútumai: id=”adatpont_típus” )&lt;br /&gt;
Az adatpont típus lehetséges értékei:&lt;br /&gt;
1 szerver&lt;br /&gt;
2 adatbázis&lt;br /&gt;
16 kliens számláló&lt;br /&gt;
17 kliens&lt;br /&gt;
Az elem tartalma egy eseménykategória azonosítója, ebbe a kategóriába fog tartozni az a treatment, amellyel az adatbont normálistól eltérő állapotai kerülnek.&lt;br /&gt;
AlgorexHandler és AlgorexMultiportHandler&lt;br /&gt;
Az Algorex protokollal operáló adatpontok kezelője, illetve ennek a Hot-standby párja konfigurációi.&lt;br /&gt;
sockettimeout&lt;br /&gt;
Az alközponthoz kapcsolódás timeout-ja.&lt;br /&gt;
socketkeepalive&lt;br /&gt;
Az életjel telegram értéke, minden esetben 0x01.&lt;br /&gt;
BACnetHandler&lt;br /&gt;
A BACnet protokollal kommunikáló adatpontok kezelőjének konfigurációja.&lt;br /&gt;
disabled-types&lt;br /&gt;
Az import során az itt felsorolt típusú elemek figyelmen kívül hagyja.&lt;br /&gt;
item&lt;br /&gt;
Értéke a tiltandó típus neve, pl.: EO_FI_ZoneManualElem&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
CerbanHandler és CerbanMultiportHandler&lt;br /&gt;
A Cerban protokollal működő adatpontok kezelője, illetve ennek a Hot-standby párja konfigurációi.&lt;br /&gt;
sockettimeout&lt;br /&gt;
Az alközponthoz kapcsolódás timeout-ja.&lt;br /&gt;
socketkeepalive&lt;br /&gt;
Az életjel telegram értéke, minden esetben 0x01.&lt;br /&gt;
SIAHandler&lt;br /&gt;
A SIA protokolhoz tartozó adatpontok kezelőjének konfigurációja.&lt;br /&gt;
Egyelőre nincs konfigurációs lehetőség.&lt;br /&gt;
RmiService&lt;br /&gt;
A szerver-kliens kapcsolatokat kezelő szervíz konfigurációja.&lt;br /&gt;
port&lt;br /&gt;
A kapcsolatokat fogadó (Registry) port száma. Alapértelmezett értéke: 1899.&lt;br /&gt;
sessiontimeout&lt;br /&gt;
A kapcsolatok elévülési ideje, ennyi (milliszekundum) inaktivitás után bontja a kapcsolatot a szerver. Alapértelmezetten: 6000.&lt;br /&gt;
sessioncheckperiod&lt;br /&gt;
A kapcsolatok elévülését ellenőrző ütemező periódusideje. Alapértelmezetten: 5000.&lt;br /&gt;
clientcount&lt;br /&gt;
Az egyszerre csatlakozott kliensek elvárt száma. &lt;br /&gt;
separate-acknowledge&lt;br /&gt;
Lehetséges értékei: true vagy false, alapértelmezetten: true.&lt;br /&gt;
Igaz értéke esetén minden kliensen külön-külön le kell nyugtázni egy új eseményt, hamis értéke esetén valamely kliens nyugtája az összes kliensen nyugtázza az eseményt.&lt;br /&gt;
pre-cache&lt;br /&gt;
Lehetséges értékei: true vagy false, alapértelmezetten: false.&lt;br /&gt;
Igaz értéke esetén induláskor betölti cache-be a treatmentek és parancsok listáját.&lt;br /&gt;
enabled-locales&lt;br /&gt;
Az engedélyezett nyelvek kódjainak felsorolása. Alapértelmezetten: en és hu.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
event-log&lt;br /&gt;
Eseménymemóriával kapcsolatos konfiguráció. (Opcionális)&lt;br /&gt;
limit&lt;br /&gt;
Az eseménymemória mérethatára, ez felett kerül archiválásra. Alapértelmezetten: 50000.&lt;br /&gt;
starttime&lt;br /&gt;
Az eseménymemóri vizsgálatának kezdete naponta (óra:perc). Alapértelmezetten a szerver indulásakor indul az ütemezés.&lt;br /&gt;
AuthenticationService&lt;br /&gt;
A felhasználók kezelésével kapcsolatos szervíz konfigurációja.&lt;br /&gt;
administrator&lt;br /&gt;
Az adminisztrátor felhasználóra vonatkozó információk, amennyiben a felhasználó még nem létezik, ezekkel az adatokkal fogja létrehozni. A belépési információkat (felhasználónév, jelszó) első indításkor fogja kérni a szerver.&lt;br /&gt;
firstname&lt;br /&gt;
lastname&lt;br /&gt;
email&lt;br /&gt;
language&lt;br /&gt;
A felhasználói felület nyelvének kódja.&lt;br /&gt;
ScriptService&lt;br /&gt;
A scriptek futtatásáért felelős szervíz konfigurációja.&lt;br /&gt;
categories&lt;br /&gt;
Script kategóriák felsorolása, lásd a Siwenoid Scripting dokumentációt.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
apis&lt;br /&gt;
Script API-k felsorolása, lásd a Siwenoid Scripting dokumentációt.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
SignalService&lt;br /&gt;
A Hot-standby megoldást implementáló szervíz konfigurációja, illetve a csatlakó JGroups5 modul beállításai. A következő 3 tulajdonság egyikének, illetve a server-list elemnek kell benne lennie:&lt;br /&gt;
1) jchannel:file&lt;br /&gt;
A csatorna konfiguriációját5 tartalmazó fájl útvonala.&lt;br /&gt;
2) jchannel:simple&lt;br /&gt;
A csatorna egyszerű konfigurációját5 tartalmazó szöveg.&lt;br /&gt;
3) jchannel:config&lt;br /&gt;
A csatorna XML konfigurációja.5&lt;br /&gt;
server-list&lt;br /&gt;
Szerverek listáját felsoroló rész.&lt;br /&gt;
server (Attribútuma: priority=”num” )&lt;br /&gt;
Egy szervert reprezentáló elem. A priority attribútum a szerver prioritását határozza meg, a nagyobb a fontosabb.&lt;br /&gt;
host&lt;br /&gt;
A szerver csatorna host címe.&lt;br /&gt;
port&lt;br /&gt;
A szerver csatorna portja.&lt;br /&gt;
License&lt;br /&gt;
A Licensszel kapcsolatos konfiguráció.&lt;br /&gt;
stick-serial&lt;br /&gt;
A mellékelt CodeMeter USB kulcs sorozatszáma.&lt;br /&gt;
firmcode&lt;br /&gt;
A gyártó kódja: 101459.&lt;br /&gt;
productcode&lt;br /&gt;
A termék kódja: 10.&lt;br /&gt;
SocketService&lt;br /&gt;
Az Algorex adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
BACnetCommunicationService&lt;br /&gt;
A BACnet adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
timeout&lt;br /&gt;
A BACnet-es kapcsolat timeout-ja. (milliszekundum)&lt;br /&gt;
Alapértelmezett: 5000.&lt;br /&gt;
instancenumber&lt;br /&gt;
A szerver BACnet azonosítója, alapértelmezetten: 100.&lt;br /&gt;
address&lt;br /&gt;
Broadcast cím, erre küldi ki a központokat kereső üzeneteket a szerver.&lt;br /&gt;
Alapértelmezetten: 255.255.255.255&lt;br /&gt;
localbindaddress&lt;br /&gt;
A helyi host címe, alapértelmezetten: 0.0.0.0&lt;br /&gt;
port&lt;br /&gt;
A BACnet port, alapértelmezetten: 47808.&lt;br /&gt;
CerbanSocketService&lt;br /&gt;
A Cerban adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
SIACommunicationService&lt;br /&gt;
A SIA adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
AndroidService&lt;br /&gt;
Az Android klienseket kezelő szervíz konfigurációja.&lt;br /&gt;
bindaddress&lt;br /&gt;
A helyi host címe, alapértelmezetten a lokális host.&lt;br /&gt;
listenport&lt;br /&gt;
A kapcsolatokat váró port száma, alapértelmezetten: 5559.&lt;br /&gt;
maxmapsize&lt;br /&gt;
A térképek maximális mérete (szélesség és magasság), alapértelmezetten: 1024.&lt;br /&gt;
IECService&lt;br /&gt;
Az IEC101 protokollal kapcsolatos szervíz konfigurációja.&lt;br /&gt;
configuration&lt;br /&gt;
A szükséges beállításokat tartalmazó fájl elérési útja.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
1 log4J XML konfiguráció: &lt;br /&gt;
http://logging.apache.org/log4j/1.2/apidocs/org/apache/log4j/xml/DOMConfigurator.html&lt;br /&gt;
&lt;br /&gt;
2 Torque konfiguráció: &lt;br /&gt;
http://db.apache.org/torque/releases/torque-3.3/runtime/reference/initialisation-configuration.html&lt;br /&gt;
Az itt leírtak a Properties fájlból való konfigurációra vonatkoznak, mely könnyedén átfordítható XML-lé: &lt;br /&gt;
A tulajdonságokban szereplő pontok az XML-ben egy-egy gyerek elemet jelentenek, pl.:&lt;br /&gt;
torque.default.connection.driver &amp;lt;&amp;gt; &amp;lt;torque&amp;gt;&amp;lt;defaults&amp;gt;&amp;lt;connection&amp;gt;&amp;lt;driver&amp;gt;...&amp;lt;/driver&amp;gt;&amp;lt;/conn...&lt;br /&gt;
&lt;br /&gt;
3 HA-JDBC dialektusok:&lt;br /&gt;
http://ha-jdbc.sourceforge.net/doc.html#dialect&lt;br /&gt;
&lt;br /&gt;
4 Cron ütemező konfigurálása:&lt;br /&gt;
http://www.quartz-scheduler.org/docs/tutorials/crontrigger.html&lt;br /&gt;
&lt;br /&gt;
5 JGroups csatorna konfiguráció:&lt;br /&gt;
http://www.jgroups.org/manual/html/user-advanced.html#d0e2444&lt;br /&gt;
Protokolok listája:&lt;br /&gt;
http://www.jgroups.org/manual/html/protlist.html&lt;br /&gt;
Egyéb információ:&lt;br /&gt;
http://community.jboss.org/wiki/JGroups&lt;/div&gt;</summary>
		<author><name>91.82.214.70</name></author>
	</entry>
	<entry>
		<id>https://wiki.siwenoid.com/index.php?title=Config_file_parameters&amp;diff=398</id>
		<title>Config file parameters</title>
		<link rel="alternate" type="text/html" href="https://wiki.siwenoid.com/index.php?title=Config_file_parameters&amp;diff=398"/>
		<updated>2010-09-25T07:27:27Z</updated>

		<summary type="html">&lt;p&gt;91.82.214.70: Created page with &amp;#039;Szerver parancssori paraméterei:  A szerver indításához minimálisan a java -jar Siwenoid.jar parancs szükséges. A további paramétereket a java és a -jar közé kell meg…&amp;#039;&lt;/p&gt;
&lt;hr /&gt;
&lt;div&gt;Szerver parancssori paraméterei:&lt;br /&gt;
&lt;br /&gt;
A szerver indításához minimálisan a java -jar Siwenoid.jar parancs szükséges. A további paramétereket a java és a -jar közé kell megadni. Főbb beállítási lehetőségek:&lt;br /&gt;
-Dsiwenoid.registry.port=1099&lt;br /&gt;
A szerver saját magát menedzselő RMI portja, ezen keresztül tudja például ellenőrizni induláskor, hogy fut-e már másik példány a számítógépen. Alapértelmezetten: 1099.&lt;br /&gt;
-Dhajdbc.home=..path..&lt;br /&gt;
Ezzel a beállítással lehet befolyásolni, hogy a HA-JDBC modul hol keresse a konfigurációs fájlját. (Általában nem kell megváltoztatni az alapértelmezettet.)&lt;br /&gt;
-Xms128m&lt;br /&gt;
A szerver induláskor ennyi memóriát foglaljon le.&lt;br /&gt;
-Xmx1024m&lt;br /&gt;
A szerver a futása során legfeljebb ennyi memóriát használhat. Az 1024m azt jelenti, hogy maximum 1024 MB. A javasolt beállítás kisebb rendszereknél -Xmx512m nagyobbaknál -Xmx1024m.&lt;br /&gt;
&lt;br /&gt;
További parancssori argumentumok (a parancs után kell írni őket szóközzel elválasztva):&lt;br /&gt;
-start&lt;br /&gt;
Elindítja a szervert (ez az alapértelmezett).&lt;br /&gt;
-stop&lt;br /&gt;
Leállítja a futó szervert.&lt;br /&gt;
-restart&lt;br /&gt;
Újraindítja a futó szervert.&lt;br /&gt;
-version&lt;br /&gt;
Kiírja a szerver verziószámát.&lt;br /&gt;
&lt;br /&gt;
Szerver oldali XML konfiguráció:&lt;br /&gt;
&lt;br /&gt;
Siwenoid&lt;br /&gt;
Gyökér elem, az XML szabvány szempontjából fontos, minden dokumentumnak pontosan egy gyökere van.&lt;br /&gt;
Services&lt;br /&gt;
A szerver által használt szervízek sorrendhelyes felsorolása. Ez alatt minden egyes elem Tag-je a szervíz osztályának egyszerű neve, tartalma pedig az osztály teljes (minősített) neve. Pl.:&lt;br /&gt;
&amp;lt;CacheService&amp;gt;hu.siwena.services.cache.CacheService&amp;lt;/CacheService&amp;gt;&lt;br /&gt;
&amp;lt;DatabaseService&amp;gt;hu.siwena.services.database.DatabaseService&amp;lt;/DatabaseService&amp;gt;&lt;br /&gt;
...&lt;br /&gt;
LoggerService&lt;br /&gt;
A logolásért felelős szervíz konfigurációja, a log4J modulnak megfelelően.1 Legegyszerűbb konfigurációja például:&lt;br /&gt;
&amp;lt;log4j:configuration xmlns:log4j=&amp;quot;http://jakarta.apache.org/log4j/&amp;quot;&amp;gt;&lt;br /&gt;
		&amp;lt;appender name=&amp;quot;root_fileappender&amp;quot; class=&amp;quot;org.apache.log4j.DailyRollingFileAppender&amp;quot;&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;File&amp;quot; value=&amp;quot;log/siwenoid.log&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;Append&amp;quot; value=&amp;quot;true&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;param name=&amp;quot;ImmediateFlush&amp;quot; value=&amp;quot;true&amp;quot;/&amp;gt;&lt;br /&gt;
&amp;lt;layout class=&amp;quot;org.apache.log4j.PatternLayout&amp;quot;&amp;gt;&lt;br /&gt;
		      		&amp;lt;param name=&amp;quot;ConversionPattern&amp;quot; value=&amp;quot;[%d] - %m%n&amp;quot;/&amp;gt;&lt;br /&gt;
 &amp;lt;/layout&amp;gt;&lt;br /&gt;
		 &amp;lt;/appender&amp;gt;&lt;br /&gt;
		&amp;lt;logger name=&amp;quot;hu.siwena&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;level value=&amp;quot;info&amp;quot;/&amp;gt;&lt;br /&gt;
			&amp;lt;appender-ref ref=&amp;quot;root_fileappender&amp;quot;/&amp;gt;&lt;br /&gt;
		&amp;lt;/logger&amp;gt;&lt;br /&gt;
		&amp;lt;appender name=&amp;quot;dbappender&amp;quot; class=&amp;quot;hu.siwena.services.database.synchronization.DatabaseErrorAppender&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;layout class=&amp;quot;org.apache.log4j.PatternLayout&amp;quot;&amp;gt;&lt;br /&gt;
				&amp;lt;param name=&amp;quot;ConversionPattern&amp;quot; value=&amp;quot;%m%n&amp;quot;/&amp;gt; 				&lt;br /&gt;
			&amp;lt;/layout&amp;gt;&lt;br /&gt;
		&amp;lt;/appender&amp;gt;&lt;br /&gt;
		&amp;lt;logger name=&amp;quot;net.sf.hajdbc&amp;quot;&amp;gt;&lt;br /&gt;
			&amp;lt;level value=&amp;quot;debug&amp;quot;/&amp;gt;&lt;br /&gt;
			&amp;lt;appender-ref ref=&amp;quot;dbappender&amp;quot;/&amp;gt;&lt;br /&gt;
		&amp;lt;/logger&amp;gt;&lt;br /&gt;
		 &amp;lt;root&amp;gt;&lt;br /&gt;
		 	 &amp;lt;level value=&amp;quot;error&amp;quot;/&amp;gt;&lt;br /&gt;
		  &amp;lt;/root&amp;gt;&lt;br /&gt;
	&amp;lt;/log4j:configuration&amp;gt;&lt;br /&gt;
DatabaseService&lt;br /&gt;
Az adatbázist kezelő szervíz konfigurációja.&lt;br /&gt;
database (Attribútumok: id=”str” host=”str” port=”num” )&lt;br /&gt;
Ilyen Tag-ekkel kell felsorolni a rendszerhez kapcsolódó adatbázisokat, az id tetszőleges, de egyedi kell legyen.&lt;br /&gt;
torque&lt;br /&gt;
A Torque modul konfigurációját tartalmazza a szabványnak megfelelően.2&lt;br /&gt;
Több adatbázis esetén ez a rész nem szükséges, csak a ha-jdbc.&lt;br /&gt;
&amp;lt;applicationRoot&amp;gt;.&amp;lt;/applicationRoot&amp;gt;&lt;br /&gt;
Az alkalmazás gyökere, mindig “.” az értéke.&lt;br /&gt;
defaults&lt;br /&gt;
Alapértelmezett értékek, konfigurációs beállítások.&lt;br /&gt;
pool&lt;br /&gt;
Szálakkal kapcsolatos beállítások.&lt;br /&gt;
&amp;lt;maxWait&amp;gt;10000&amp;lt;/maxWait&amp;gt;&lt;br /&gt;
Maximum várakozási idő, mielőtt egy kapcsolódás meghiúsulna (milliszekundum).&lt;br /&gt;
&amp;lt;maxIdle&amp;gt;20&amp;lt;/maxIdle&amp;gt;&lt;br /&gt;
Várakozó szálak maximális száma.&lt;br /&gt;
&amp;lt;maxActive&amp;gt;50&amp;lt;/maxActive&amp;gt;&lt;br /&gt;
Aktív szálak (kapcsolatok) maximális száma.&lt;br /&gt;
&amp;lt;timeBetweenEvictionRunsMillis&amp;gt;300000&amp;lt;/timeBetweenEvictionRunsMillis&amp;gt;&lt;br /&gt;
&amp;lt;minEvictableIdleTimeMillis&amp;gt;3600000&amp;lt;/minEvictableIdleTimeMillis&amp;gt;&lt;br /&gt;
connection&lt;br /&gt;
Az adatbázis kapcsolat beállításai.&lt;br /&gt;
driver&lt;br /&gt;
Az adatbáziskezelőhöz tartozó Java Driver.&lt;br /&gt;
MySQL: com.mysql.jdbc.Driver�PostgreSQL: org.postgresql.Driver&lt;br /&gt;
url&lt;br /&gt;
Az adatbáziskezelő JDBC URL-je.&lt;br /&gt;
MySQL: jdbc:mysql://host:port/adatbazisnev�PostgreSQL: jdbc:postgresql://host:port/adatbazisnev&lt;br /&gt;
user&lt;br /&gt;
Az adatbázishoz csatlakozó felhasználó neve.&lt;br /&gt;
password&lt;br /&gt;
Az adatbázishoz csatlakozó felhasználó jelszava.&lt;br /&gt;
database&lt;br /&gt;
Adatbázis tulajdonságai.&lt;br /&gt;
default&lt;br /&gt;
Az alapértelmezett adatbázis (logikai) neve&lt;br /&gt;
[az_előző_pontban_megadott_név]&lt;br /&gt;
adapter&lt;br /&gt;
Az adatbázist kezelő adapter neve, keresd a Torque dokumentációjában. Leggyakrabban a mysql vagy postgresql adaptereket használjuk.&lt;br /&gt;
dsfactory&lt;br /&gt;
DataSourceFactory - A Torque használja, javasolt az alább Factory használata.&lt;br /&gt;
[alapértelmezett_adatbazis_neve]&lt;br /&gt;
&amp;lt;factory&amp;gt;org.apache.torque.dsfactory.SharedPoolDataSourceFactory&amp;lt;/factory&amp;gt;&lt;br /&gt;
&amp;lt;idbroker.clever.quantity&amp;gt;true&amp;lt;/idbroker.clever.quantity&amp;gt;&lt;br /&gt;
&amp;lt;manager.useCache&amp;gt;true&amp;lt;/manager.useCache&amp;gt;&lt;br /&gt;
ha-jdbc (Attríbutuma: cluster=”str” )&lt;br /&gt;
Több adatbázis együttes kezelésekor szükséges, a cluster paraméter egy tetszőleges logikai név, pl.: SiwenoidDbCluster. Egy adatbázis esetén ez a rész nem szükséges, de ha ez nincs beállítva, akkor a torque résznek kell megfelelőnek lennie.&lt;br /&gt;
&amp;lt;sync id=&amp;quot;tetszőleges&amp;quot; class=&amp;quot;hu.siwena.services.database.synchronization.CustomDifferentialSynchronizationStrategy&amp;quot;/&amp;gt;&lt;br /&gt;
Adatbázisok szinkronizálását végző osztály konfigurálása.&lt;br /&gt;
cluster&lt;br /&gt;
Az adatbázis cluster konfigurálása.&lt;br /&gt;
Attribútumai:&lt;br /&gt;
balancer=&amp;quot;simple&amp;quot;&lt;br /&gt;
default-sync=&amp;quot;fentebb megadott sync id attribútumának értéke&amp;quot;&lt;br /&gt;
dialect=&amp;quot;mysql&amp;quot; lehet pl. postgresql is, lásd a HA-JDBC dokumentációját 3&lt;br /&gt;
meta-data-cache=&amp;quot;lazy&amp;quot;&lt;br /&gt;
transaction-mode=&amp;quot;parallel&amp;quot;&lt;br /&gt;
max-threads=&amp;quot;5&amp;quot;&lt;br /&gt;
auto-activate-schedule=&amp;quot;0 0/1 * * * ?&amp;quot;&lt;br /&gt;
Az adatbázisok aktiválását végző Cron ütemező futási idő konfigurációja.4&lt;br /&gt;
failure-detect-schedule=&amp;quot;0/15 * * * * ?&amp;quot;&lt;br /&gt;
Az adatbázisok kiesését vizsgáló Cron ütemező futási idő konfigurációja.4&lt;br /&gt;
Gyerek elemek:&lt;br /&gt;
database (Attribútuma: id=”a fentebb megadott id-k egyike” )&lt;br /&gt;
Egy-egy adatbázist reprezentáló elem.&lt;br /&gt;
driver&lt;br /&gt;
Lásd torque.defaults.connection.driver.&lt;br /&gt;
url&lt;br /&gt;
Lásd torque.defaults.connection.url.&lt;br /&gt;
user&lt;br /&gt;
Lásd torque.defaults.connection.user.&lt;br /&gt;
password&lt;br /&gt;
Lásd torque.defaults.connection.password.&lt;br /&gt;
database&lt;br /&gt;
....&lt;br /&gt;
DataPointService&lt;br /&gt;
Az adatpontokkal kapcsolatos szervíz konfigurációja, ez definiálja a használandó adatpont kezelőket is.&lt;br /&gt;
rootcontainername&lt;br /&gt;
A gyökér konténer neve, alapértelmezetten root.&lt;br /&gt;
systemcontainername&lt;br /&gt;
A rendszer konténer neve, alapértelmezetten system.&lt;br /&gt;
pre-cache&lt;br /&gt;
Töltse-e be az adatpontokat és gyerek listáikat automatikusan a cache-be induláskor. Az alapértelmezett érték: false. Lehetséges értékek: true vagy false.&lt;br /&gt;
import-memory-opts&lt;br /&gt;
Az adatpont importáló alkalmazás indításakor használandó memóriaszabályzó paraméter. Pl. -Xmx512m azt jelenti, hogy az alkalmazás max. 512 MB memóriát fog tudni használni.&lt;br /&gt;
Az alapértelmezett érték: -Xmx512m.&lt;br /&gt;
datapointhandlers&lt;br /&gt;
Adatpontkezelők felsorolása. Minden “item” Tag-be egy-egy kezelő teljes (minősített) nevét kell írni.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
Például:&lt;br /&gt;
&amp;lt;item&amp;gt;hu.siwena.services.datapoint.handlers.SystemHandler&amp;lt;/item&amp;gt;&lt;br /&gt;
&amp;lt;item&amp;gt;hu.siwena.services.datapoint.handlers.AlgorexHandler&amp;lt;/item&amp;gt;&lt;br /&gt;
SystemHandler&lt;br /&gt;
A rendszer-adatpontokat kezelő osztály konfigurációja.&lt;br /&gt;
type (Attribútumai: id=”adatpont_típus” )&lt;br /&gt;
Az adatpont típus lehetséges értékei:&lt;br /&gt;
1 szerver&lt;br /&gt;
2 adatbázis&lt;br /&gt;
16 kliens számláló&lt;br /&gt;
17 kliens&lt;br /&gt;
Az elem tartalma egy eseménykategória azonosítója, ebbe a kategóriába fog tartozni az a treatment, amellyel az adatbont normálistól eltérő állapotai kerülnek.&lt;br /&gt;
AlgorexHandler és AlgorexMultiportHandler&lt;br /&gt;
Az Algorex protokollal operáló adatpontok kezelője, illetve ennek a Hot-standby párja konfigurációi.&lt;br /&gt;
sockettimeout&lt;br /&gt;
Az alközponthoz kapcsolódás timeout-ja.&lt;br /&gt;
socketkeepalive&lt;br /&gt;
Az életjel telegram értéke, minden esetben 0x01.&lt;br /&gt;
BACnetHandler&lt;br /&gt;
A BACnet protokollal kommunikáló adatpontok kezelőjének konfigurációja.&lt;br /&gt;
disabled-types&lt;br /&gt;
Az import során az itt felsorolt típusú elemek figyelmen kívül hagyja.&lt;br /&gt;
item&lt;br /&gt;
Értéke a tiltandó típus neve, pl.: EO_FI_ZoneManualElem&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
CerbanHandler és CerbanMultiportHandler&lt;br /&gt;
A Cerban protokollal működő adatpontok kezelője, illetve ennek a Hot-standby párja konfigurációi.&lt;br /&gt;
sockettimeout&lt;br /&gt;
Az alközponthoz kapcsolódás timeout-ja.&lt;br /&gt;
socketkeepalive&lt;br /&gt;
Az életjel telegram értéke, minden esetben 0x01.&lt;br /&gt;
SIAHandler&lt;br /&gt;
A SIA protokolhoz tartozó adatpontok kezelőjének konfigurációja.&lt;br /&gt;
Egyelőre nincs konfigurációs lehetőség.&lt;br /&gt;
RmiService&lt;br /&gt;
A szerver-kliens kapcsolatokat kezelő szervíz konfigurációja.&lt;br /&gt;
port&lt;br /&gt;
A kapcsolatokat fogadó (Registry) port száma. Alapértelmezett értéke: 1899.&lt;br /&gt;
sessiontimeout&lt;br /&gt;
A kapcsolatok elévülési ideje, ennyi (milliszekundum) inaktivitás után bontja a kapcsolatot a szerver. Alapértelmezetten: 6000.&lt;br /&gt;
sessioncheckperiod&lt;br /&gt;
A kapcsolatok elévülését ellenőrző ütemező periódusideje. Alapértelmezetten: 5000.&lt;br /&gt;
clientcount&lt;br /&gt;
Az egyszerre csatlakozott kliensek elvárt száma. &lt;br /&gt;
separate-acknowledge&lt;br /&gt;
Lehetséges értékei: true vagy false, alapértelmezetten: true.&lt;br /&gt;
Igaz értéke esetén minden kliensen külön-külön le kell nyugtázni egy új eseményt, hamis értéke esetén valamely kliens nyugtája az összes kliensen nyugtázza az eseményt.&lt;br /&gt;
pre-cache&lt;br /&gt;
Lehetséges értékei: true vagy false, alapértelmezetten: false.&lt;br /&gt;
Igaz értéke esetén induláskor betölti cache-be a treatmentek és parancsok listáját.&lt;br /&gt;
enabled-locales&lt;br /&gt;
Az engedélyezett nyelvek kódjainak felsorolása. Alapértelmezetten: en és hu.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
event-log&lt;br /&gt;
Eseménymemóriával kapcsolatos konfiguráció. (Opcionális)&lt;br /&gt;
limit&lt;br /&gt;
Az eseménymemória mérethatára, ez felett kerül archiválásra. Alapértelmezetten: 50000.&lt;br /&gt;
starttime&lt;br /&gt;
Az eseménymemóri vizsgálatának kezdete naponta (óra:perc). Alapértelmezetten a szerver indulásakor indul az ütemezés.&lt;br /&gt;
AuthenticationService&lt;br /&gt;
A felhasználók kezelésével kapcsolatos szervíz konfigurációja.&lt;br /&gt;
administrator&lt;br /&gt;
Az adminisztrátor felhasználóra vonatkozó információk, amennyiben a felhasználó még nem létezik, ezekkel az adatokkal fogja létrehozni. A belépési információkat (felhasználónév, jelszó) első indításkor fogja kérni a szerver.&lt;br /&gt;
firstname&lt;br /&gt;
lastname&lt;br /&gt;
email&lt;br /&gt;
language&lt;br /&gt;
A felhasználói felület nyelvének kódja.&lt;br /&gt;
ScriptService&lt;br /&gt;
A scriptek futtatásáért felelős szervíz konfigurációja.&lt;br /&gt;
categories&lt;br /&gt;
Script kategóriák felsorolása, lásd a Siwenoid Scripting dokumentációt.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
apis&lt;br /&gt;
Script API-k felsorolása, lásd a Siwenoid Scripting dokumentációt.&lt;br /&gt;
item&lt;br /&gt;
item&lt;br /&gt;
...&lt;br /&gt;
SignalService&lt;br /&gt;
A Hot-standby megoldást implementáló szervíz konfigurációja, illetve a csatlakó JGroups5 modul beállításai. A következő 3 tulajdonság egyikének, illetve a server-list elemnek kell benne lennie:&lt;br /&gt;
1) jchannel:file&lt;br /&gt;
A csatorna konfiguriációját5 tartalmazó fájl útvonala.&lt;br /&gt;
2) jchannel:simple&lt;br /&gt;
A csatorna egyszerű konfigurációját5 tartalmazó szöveg.&lt;br /&gt;
3) jchannel:config&lt;br /&gt;
A csatorna XML konfigurációja.5&lt;br /&gt;
server-list&lt;br /&gt;
Szerverek listáját felsoroló rész.&lt;br /&gt;
server (Attribútuma: priority=”num” )&lt;br /&gt;
Egy szervert reprezentáló elem. A priority attribútum a szerver prioritását határozza meg, a nagyobb a fontosabb.&lt;br /&gt;
host&lt;br /&gt;
A szerver csatorna host címe.&lt;br /&gt;
port&lt;br /&gt;
A szerver csatorna portja.&lt;br /&gt;
License&lt;br /&gt;
A Licensszel kapcsolatos konfiguráció.&lt;br /&gt;
stick-serial&lt;br /&gt;
A mellékelt CodeMeter USB kulcs sorozatszáma.&lt;br /&gt;
firmcode&lt;br /&gt;
A gyártó kódja: 101459.&lt;br /&gt;
productcode&lt;br /&gt;
A termék kódja: 10.&lt;br /&gt;
SocketService&lt;br /&gt;
Az Algorex adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
BACnetCommunicationService&lt;br /&gt;
A BACnet adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
timeout&lt;br /&gt;
A BACnet-es kapcsolat timeout-ja. (milliszekundum)&lt;br /&gt;
Alapértelmezett: 5000.&lt;br /&gt;
instancenumber&lt;br /&gt;
A szerver BACnet azonosítója, alapértelmezetten: 100.&lt;br /&gt;
address&lt;br /&gt;
Broadcast cím, erre küldi ki a központokat kereső üzeneteket a szerver.&lt;br /&gt;
Alapértelmezetten: 255.255.255.255&lt;br /&gt;
localbindaddress&lt;br /&gt;
A helyi host címe, alapértelmezetten: 0.0.0.0&lt;br /&gt;
port&lt;br /&gt;
A BACnet port, alapértelmezetten: 47808.&lt;br /&gt;
CerbanSocketService&lt;br /&gt;
A Cerban adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
SIACommunicationService&lt;br /&gt;
A SIA adatpont kezelőhoz tartozó kommunikációs szervíz konfigurációja.&lt;br /&gt;
poolsize&lt;br /&gt;
Párhuzamos szálak száma, események érkezésekor.&lt;br /&gt;
Alapértelmezetten: 5.&lt;br /&gt;
AndroidService&lt;br /&gt;
Az Android klienseket kezelő szervíz konfigurációja.&lt;br /&gt;
bindaddress&lt;br /&gt;
A helyi host címe, alapértelmezetten a lokális host.&lt;br /&gt;
listenport&lt;br /&gt;
A kapcsolatokat váró port száma, alapértelmezetten: 5559.&lt;br /&gt;
maxmapsize&lt;br /&gt;
A térképek maximális mérete (szélesség és magasság), alapértelmezetten: 1024.&lt;br /&gt;
IECService&lt;br /&gt;
Az IEC101 protokollal kapcsolatos szervíz konfigurációja.&lt;br /&gt;
configuration&lt;br /&gt;
A szükséges beállításokat tartalmazó fájl elérési útja.&lt;br /&gt;
&lt;br /&gt;
&lt;br /&gt;
1 log4J XML konfiguráció: &lt;br /&gt;
http://logging.apache.org/log4j/1.2/apidocs/org/apache/log4j/xml/DOMConfigurator.html&lt;br /&gt;
&lt;br /&gt;
2 Torque konfiguráció: &lt;br /&gt;
http://db.apache.org/torque/releases/torque-3.3/runtime/reference/initialisation-configuration.html&lt;br /&gt;
Az itt leírtak a Properties fájlból való konfigurációra vonatkoznak, mely könnyedén átfordítható XML-lé: &lt;br /&gt;
A tulajdonságokban szereplő pontok az XML-ben egy-egy gyerek elemet jelentenek, pl.:&lt;br /&gt;
torque.default.connection.driver &amp;lt;&amp;gt; &amp;lt;torque&amp;gt;&amp;lt;defaults&amp;gt;&amp;lt;connection&amp;gt;&amp;lt;driver&amp;gt;...&amp;lt;/driver&amp;gt;&amp;lt;/conn...&lt;br /&gt;
&lt;br /&gt;
3 HA-JDBC dialektusok:&lt;br /&gt;
http://ha-jdbc.sourceforge.net/doc.html#dialect&lt;br /&gt;
&lt;br /&gt;
4 Cron ütemező konfigurálása:&lt;br /&gt;
http://www.quartz-scheduler.org/docs/tutorials/crontrigger.html&lt;br /&gt;
&lt;br /&gt;
5 JGroups csatorna konfiguráció:&lt;br /&gt;
http://www.jgroups.org/manual/html/user-advanced.html#d0e2444&lt;br /&gt;
Protokolok listája:&lt;br /&gt;
http://www.jgroups.org/manual/html/protlist.html&lt;br /&gt;
Egyéb információ:&lt;br /&gt;
http://community.jboss.org/wiki/JGroups&lt;/div&gt;</summary>
		<author><name>91.82.214.70</name></author>
	</entry>
</feed>